Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 149
Filter
1.
Cardiooncology ; 10(1): 7, 2024 Feb 09.
Article in English | MEDLINE | ID: mdl-38336705

ABSTRACT

BACKGROUND: Thoracic radiotherapy may damage the myocardium and arteries, increasing cardiovascular disease (CVD) risk. Women with a high local breast cancer (BC) recurrence risk may receive an additional radiation boost to the tumor bed. OBJECTIVE: We aimed to evaluate the CVD risk and specifically ischemic heart disease (IHD) in BC patients treated with a radiation boost, and investigated whether this was modified by age. METHODS: We identified 5260 BC patients receiving radiotherapy between 2005 and 2016 without a history of CVD. Boost data were derived from hospital records and the national cancer registry. Follow-up data on CVD events were obtained from Statistics Netherlands until December 31, 2018. The relation between CVD and boost was evaluated with competing risk survival analysis. RESULTS: 1917 (36.4%) received a boost. Mean follow-up was 80.3 months (SD37.1) and the mean age 57.8 years (SD10.7). Interaction between boost and age was observed for IHD: a boost was significantly associated with IHD incidence in patients younger than 40 years but not in patients over 40 years. The subdistribution hazard ratio (sHR) was calculated for ages from 25 to 75 years, showing a sHR range from 5.1 (95%CI 1.2-22.6) for 25-year old patients to sHR 0.5 (95%CI 0.2-1.02) for 75-year old patients. CONCLUSION: In patients younger than 40, a radiation boost is significantly associated with an increased risk of CVD. In absolute terms, the increased risk was low. In older patients, there was no association between boost and CVD risk, which is likely a reflection of appropriate patient selection.

2.
ArXiv ; 2024 Jan 24.
Article in English | MEDLINE | ID: mdl-38344221

ABSTRACT

Connectivity matrices derived from diffusion MRI (dMRI) provide an interpretable and generalizable way of understanding the human brain connectome. However, dMRI suffers from inter-site and between-scanner variation, which impedes analysis across datasets to improve robustness and reproducibility of results. To evaluate different harmonization approaches on connectivity matrices, we compared graph measures derived from these matrices before and after applying three harmonization techniques: mean shift, ComBat, and CycleGAN. The sample comprises 168 age-matched, sex-matched normal subjects from two studies: the Vanderbilt Memory and Aging Project (VMAP) and the Biomarkers of Cognitive Decline Among Normal Individuals (BIOCARD). First, we plotted the graph measures and used coefficient of variation (CoV) and the Mann-Whitney U test to evaluate different methods' effectiveness in removing site effects on the matrices and the derived graph measures. ComBat effectively eliminated site effects for global efficiency and modularity and outperformed the other two methods. However, all methods exhibited poor performance when harmonizing average betweenness centrality. Second, we tested whether our harmonization methods preserved correlations between age and graph measures. All methods except for CycleGAN in one direction improved correlations between age and global efficiency and between age and modularity from insignificant to significant with p-values less than 0.05.

3.
IEEE Trans Med Imaging ; 43(2): 784-793, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37782589

ABSTRACT

Recent works in medical image registration have proposed the use of Implicit Neural Representations, demonstrating performance that rivals state-of-the-art learning-based methods. However, these implicit representations need to be optimized for each new image pair, which is a stochastic process that may fail to converge to a global minimum. To improve robustness, we propose a deformable registration method using pairs of cycle-consistent Implicit Neural Representations: each implicit representation is linked to a second implicit representation that estimates the opposite transformation, causing each network to act as a regularizer for its paired opposite. During inference, we generate multiple deformation estimates by numerically inverting the paired backward transformation and evaluating the consensus of the optimized pair. This consensus improves registration accuracy over using a single representation and results in a robust uncertainty metric that can be used for automatic quality control. We evaluate our method with a 4D lung CT dataset. The proposed cycle-consistent optimization method reduces the optimization failure rate from 2.4% to 0.0% compared to the current state-of-the-art. The proposed inference method improves landmark accuracy by 4.5% and the proposed uncertainty metric detects all instances where the registration method fails to converge to a correct solution. We verify the generalizability of these results to other data using a centerline propagation task in abdominal 4D MRI, where our method achieves a 46% improvement in propagation consistency compared with single-INR registration and demonstrates a strong correlation between the proposed uncertainty metric and registration accuracy.


Subject(s)
Four-Dimensional Computed Tomography , Lung , Four-Dimensional Computed Tomography/methods , Lung/diagnostic imaging , Thorax , Image Processing, Computer-Assisted/methods , Algorithms
4.
ArXiv ; 2024 Jan 21.
Article in English | MEDLINE | ID: mdl-37986731

ABSTRACT

Imaging findings inconsistent with those expected at specific chronological age ranges may serve as early indicators of neurological disorders and increased mortality risk. Estimation of chronological age, and deviations from expected results, from structural magnetic resonance imaging (MRI) data has become an important proxy task for developing biomarkers that are sensitive to such deviations. Complementary to structural analysis, diffusion tensor imaging (DTI) has proven effective in identifying age-related microstructural changes within the brain white matter, thereby presenting itself as a promising additional modality for brain age prediction. Although early studies have sought to harness DTI's advantages for age estimation, there is no evidence that the success of this prediction is owed to the unique microstructural and diffusivity features that DTI provides, rather than the macrostructural features that are also available in DTI data. Therefore, we seek to develop white-matter-specific age estimation to capture deviations from normal white matter aging. Specifically, we deliberately disregard the macrostructural information when predicting age from DTI scalar images, using two distinct methods. The first method relies on extracting only microstructural features from regions of interest (ROIs). The second applies 3D residual neural networks (ResNets) to learn features directly from the images, which are non-linearly registered and warped to a template to minimize macrostructural variations. When tested on unseen data, the first method yields mean absolute error (MAE) of 6.11 ± 0.19 years for cognitively normal participants and MAE of 6.62 ± 0.30 years for cognitively impaired participants, while the second method achieves MAE of 4.69 ± 0.23 years for cognitively normal participants and MAE of 4.96 ± 0.28 years for cognitively impaired participants. We find that the ResNet model captures subtler, non-macrostructural features for brain age prediction.

5.
IEEE Trans Med Imaging ; 43(4): 1272-1283, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37862273

ABSTRACT

Coronary artery disease (CAD) remains the leading cause of death worldwide. Patients with suspected CAD undergo coronary CT angiography (CCTA) to evaluate the risk of cardiovascular events and determine the treatment. Clinical analysis of coronary arteries in CCTA comprises the identification of atherosclerotic plaque, as well as the grading of any coronary artery stenosis typically obtained through the CAD-Reporting and Data System (CAD-RADS). This requires analysis of the coronary lumen and plaque. While voxel-wise segmentation is a commonly used approach in various segmentation tasks, it does not guarantee topologically plausible shapes. To address this, in this work, we propose to directly infer surface meshes for coronary artery lumen and plaque based on a centerline prior and use it in the downstream task of CAD-RADS scoring. The method is developed and evaluated using a total of 2407 CCTA scans. Our method achieved lesion-wise volume intraclass correlation coefficients of 0.98, 0.79, and 0.85 for calcified, non-calcified, and total plaque volume respectively. Patient-level CAD-RADS categorization was evaluated on a representative hold-out test set of 300 scans, for which the achieved linearly weighted kappa ( κ ) was 0.75. CAD-RADS categorization on the set of 658 scans from another hospital and scanner led to a κ of 0.71. The results demonstrate that direct inference of coronary artery meshes for lumen and plaque is feasible, and allows for the automated prediction of routinely performed CAD-RADS categorization.


Subject(s)
Coronary Artery Disease , Plaque, Atherosclerotic , Humans , Computed Tomography Angiography/methods , Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Coronary Vessels/diagnostic imaging , Plaque, Atherosclerotic/diagnostic imaging , Predictive Value of Tests
6.
EBioMedicine ; 99: 104937, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38118401

ABSTRACT

BACKGROUND: Risk stratification for ventricular arrhythmias currently relies on static measurements that fail to adequately capture dynamic interactions between arrhythmic substrate and triggers over time. We trained and internally validated a dynamic machine learning (ML) model and neural network that extracted features from longitudinally collected electrocardiograms (ECG), and used these to predict the risk of malignant ventricular arrhythmias. METHODS: A multicentre study in patients implanted with an implantable cardioverter-defibrillator (ICD) between 2007 and 2021 in two academic hospitals was performed. Variational autoencoders (VAEs), which combine neural networks with variational inference principles, and can learn patterns and structure in data without explicit labelling, were trained to encode the mean ECG waveforms from the limb leads into 16 variables. Supervised dynamic ML models using these latent ECG representations and clinical baseline information were trained to predict malignant ventricular arrhythmias treated by the ICD. Model performance was evaluated on a hold-out set, using time-dependent receiver operating characteristic (ROC) and calibration curves. FINDINGS: 2942 patients (61.7 ± 13.9 years, 25.5% female) were included, with a total of 32,129 ECG recordings during a mean follow-up of 43.9 ± 35.9 months. The mean time-varying area under the ROC curve for the dynamic model was 0.738 ± 0.07, compared to 0.639 ± 0.03 for a static (i.e. baseline-only model). Feature analyses indicated dynamic changes in latent ECG representations, particularly those affecting the T-wave morphology, were of highest importance for model predictions. INTERPRETATION: Dynamic ML models and neural networks effectively leverage routinely collected longitudinal ECG recordings for personalised and updated predictions of malignant ventricular arrhythmias, outperforming static models. FUNDING: This publication is part of the project DEEP RISK ICD (with project number 452019308) of the research programme Rubicon which is (partly) financed by the Dutch Research Council (NWO). This research is partly funded by the Amsterdam Cardiovascular Sciences (personal grant F.V.Y.T).


Subject(s)
Defibrillators, Implantable , Humans , Female , Male , Death, Sudden, Cardiac , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/therapy , Electrocardiography , Neural Networks, Computer
7.
Nat Rev Cardiol ; 21(1): 51-64, 2024 01.
Article in English | MEDLINE | ID: mdl-37464183

ABSTRACT

Artificial intelligence (AI) is likely to revolutionize the way medical images are analysed and has the potential to improve the identification and analysis of vulnerable or high-risk atherosclerotic plaques in coronary arteries, leading to advances in the treatment of coronary artery disease. However, coronary plaque analysis is challenging owing to cardiac and respiratory motion, as well as the small size of cardiovascular structures. Moreover, the analysis of coronary imaging data is time-consuming, can be performed only by clinicians with dedicated cardiovascular imaging training, and is subject to considerable interreader and intrareader variability. AI has the potential to improve the assessment of images of vulnerable plaque in coronary arteries, but requires robust development, testing and validation. Combining human expertise with AI might facilitate the reliable and valid interpretation of images obtained using CT, MRI, PET, intravascular ultrasonography and optical coherence tomography. In this Roadmap, we review existing evidence on the application of AI to the imaging of vulnerable plaque in coronary arteries and provide consensus recommendations developed by an interdisciplinary group of experts on AI and non-invasive and invasive coronary imaging. We also outline future requirements of AI technology to address bias, uncertainty, explainability and generalizability, which are all essential for the acceptance of AI and its clinical utility in handling the anticipated growing volume of coronary imaging procedures.


Subject(s)
Coronary Artery Disease , Plaque, Atherosclerotic , Humans , Plaque, Atherosclerotic/diagnostic imaging , Artificial Intelligence , Coronary Vessels/diagnostic imaging , Coronary Artery Disease/diagnostic imaging , Tomography, Optical Coherence/methods , Coronary Angiography
8.
Comput Biol Med ; 167: 107602, 2023 12.
Article in English | MEDLINE | ID: mdl-37925906

ABSTRACT

Accurate prediction of fetal weight at birth is essential for effective perinatal care, particularly in the context of antenatal management, which involves determining the timing and mode of delivery. The current standard of care involves performing a prenatal ultrasound 24 hours prior to delivery. However, this task presents challenges as it requires acquiring high-quality images, which becomes difficult during advanced pregnancy due to the lack of amniotic fluid. In this paper, we present a novel method that automatically predicts fetal birth weight by using fetal ultrasound video scans and clinical data. Our proposed method is based on a Transformer-based approach that combines a Residual Transformer Module with a Dynamic Affine Feature Map Transform. This method leverages tabular clinical data to evaluate 2D+t spatio-temporal features in fetal ultrasound video scans. Development and evaluation were carried out on a clinical set comprising 582 2D fetal ultrasound videos and clinical records of pregnancies from 194 patients performed less than 24 hours before delivery. Our results show that our method outperforms several state-of-the-art automatic methods and estimates fetal birth weight with an accuracy comparable to human experts. Hence, automatic measurements obtained by our method can reduce the risk of errors inherent in manual measurements. Observer studies suggest that our approach may be used as an aid for less experienced clinicians to predict fetal birth weight before delivery, optimizing perinatal care regardless of the available expertise.


Subject(s)
Fetal Weight , Ultrasonography, Prenatal , Infant, Newborn , Pregnancy , Humans , Female , Birth Weight , Ultrasonography, Prenatal/methods , Biometry
9.
Sci Rep ; 13(1): 16875, 2023 10 06.
Article in English | MEDLINE | ID: mdl-37803027

ABSTRACT

Label noise hampers supervised training of neural networks. However, data without label noise is often infeasible to attain, especially for medical tasks. Attaining high-quality medical labels would require a pool of experts and their consensus reading, which would be extremely costly. Several methods have been proposed to mitigate the adverse effects of label noise during training. State-of-the-art methods use multiple networks that exploit different decision boundaries to identify label noise. Among the best performing methods is co-teaching. However, co-teaching comes with the requirement of knowing label noise a priori. Hence, we propose a co-teaching method that does not require any prior knowledge about the level of label noise. We introduce stochasticity to select or reject training instances. We have extensively evaluated the method on synthetic experiments with extreme label noise levels and applied it to real-world medical problems of ECG classification and cardiac MRI segmentation. Results show that the approach is robust to its hyperparameter choice and applies to various classification tasks with unknown levels of label noise.


Subject(s)
Drug-Related Side Effects and Adverse Reactions , Humans , Consensus , Knowledge , Neural Networks, Computer
10.
Med Image Anal ; 90: 102971, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37778103

ABSTRACT

CT perfusion imaging is important in the imaging workup of acute ischemic stroke for evaluating affected cerebral tissue. CT perfusion analysis software produces cerebral perfusion maps from commonly noisy spatio-temporal CT perfusion data. High levels of noise can influence the results of CT perfusion analysis, necessitating software tuning. This work proposes a novel approach for CT perfusion analysis that uses physics-informed learning, an optimization framework that is robust to noise. In particular, we propose SPPINN: Spatio-temporal Perfusion Physics-Informed Neural Network and research spatio-temporal physics-informed learning. SPPINN learns implicit neural representations of contrast attenuation in CT perfusion scans using the spatio-temporal coordinates of the data and employs these representations to estimate a continuous representation of the cerebral perfusion parameters. We validate the approach on simulated data to quantify perfusion parameter estimation performance. Furthermore, we apply the method to in-house patient data and the public Ischemic Stroke Lesion Segmentation 2018 benchmark data to assess the correspondence between the perfusion maps and reference standard infarct core segmentations. Our method achieves accurate perfusion parameter estimates even with high noise levels and differentiates healthy tissue from infarcted tissue. Moreover, SPPINN perfusion maps accurately correspond with reference standard infarct core segmentations. Hence, we show that using spatio-temporal physics-informed learning for cerebral perfusion estimation is accurate, even in noisy CT perfusion data. The code for this work is available at https://github.com/lucasdevries/SPPINN.


Subject(s)
Brain Ischemia , Ischemic Stroke , Stroke , Humans , Tomography, X-Ray Computed/methods , Perfusion , Infarction , Stroke/diagnostic imaging , Brain Ischemia/diagnostic imaging , Cerebrovascular Circulation , Perfusion Imaging/methods
11.
Am J Obstet Gynecol MFM ; 5(12): 101182, 2023 12.
Article in English | MEDLINE | ID: mdl-37821009

ABSTRACT

BACKGROUND: Fetal weight is currently estimated from fetal biometry parameters using heuristic mathematical formulas. Fetal biometry requires measurements of the fetal head, abdomen, and femur. However, this examination is prone to inter- and intraobserver variability because of factors, such as the experience of the operator, image quality, maternal characteristics, or fetal movements. Our study tested the hypothesis that a deep learning method can estimate fetal weight based on a video scan of the fetal abdomen and gestational age with similar performance to the full biometry-based estimations provided by clinical experts. OBJECTIVE: This study aimed to develop and test a deep learning method to automatically estimate fetal weight from fetal abdominal ultrasound video scans. STUDY DESIGN: A dataset of 900 routine fetal ultrasound examinations was used. Among those examinations, 800 retrospective ultrasound video scans of the fetal abdomen from 700 pregnant women between 15 6/7 and 41 0/7 weeks of gestation were used to train the deep learning model. After the training phase, the model was evaluated on an external prospectively acquired test set of 100 scans from 100 pregnant women between 16 2/7 and 38 0/7 weeks of gestation. The deep learning model was trained to directly estimate fetal weight from ultrasound video scans of the fetal abdomen. The deep learning estimations were compared with manual measurements on the test set made by 6 human readers with varying levels of expertise. Human readers used standard 3 measurements made on the standard planes of the head, abdomen, and femur and heuristic formula to estimate fetal weight. The Bland-Altman analysis, mean absolute percentage error, and intraclass correlation coefficient were used to evaluate the performance and robustness of the deep learning method and were compared with human readers. RESULTS: Bland-Altman analysis did not show systematic deviations between readers and deep learning. The mean and standard deviation of the mean absolute percentage error between 6 human readers and the deep learning approach was 3.75%±2.00%. Excluding junior readers (residents), the mean absolute percentage error between 4 experts and the deep learning approach was 2.59%±1.11%. The intraclass correlation coefficients reflected excellent reliability and varied between 0.9761 and 0.9865. CONCLUSION: This study reports the use of deep learning to estimate fetal weight using only ultrasound video of the fetal abdomen from fetal biometry scans. Our experiments demonstrated similar performance of human measurements and deep learning on prospectively acquired test data. Deep learning is a promising approach to directly estimate fetal weight using ultrasound video scans of the fetal abdomen.


Subject(s)
Deep Learning , Fetal Weight , Pregnancy , Female , Humans , Retrospective Studies , Reproducibility of Results , Abdomen/diagnostic imaging
12.
Europace ; 25(9)2023 08 02.
Article in English | MEDLINE | ID: mdl-37712675

ABSTRACT

AIMS: Left ventricular ejection fraction (LVEF) is suboptimal as a sole marker for predicting sudden cardiac death (SCD). Machine learning (ML) provides new opportunities for personalized predictions using complex, multimodal data. This study aimed to determine if risk stratification for implantable cardioverter-defibrillator (ICD) implantation can be improved by ML models that combine clinical variables with 12-lead electrocardiograms (ECG) time-series features. METHODS AND RESULTS: A multicentre study of 1010 patients (64.9 ± 10.8 years, 26.8% female) with ischaemic, dilated, or non-ischaemic cardiomyopathy, and LVEF ≤ 35% implanted with an ICD between 2007 and 2021 for primary prevention of SCD in two academic hospitals was performed. For each patient, a raw 12-lead, 10-s ECG was obtained within 90 days before ICD implantation, and clinical details were collected. Supervised ML models were trained and validated on a development cohort (n = 550) from Hospital A to predict ICD non-arrhythmic mortality at three-year follow-up (i.e. mortality without prior appropriate ICD-therapy). Model performance was evaluated on an external patient cohort from Hospital B (n = 460). At three-year follow-up, 16.0% of patients had died, with 72.8% meeting criteria for non-arrhythmic mortality. Extreme gradient boosting models identified patients with non-arrhythmic mortality with an area under the receiver operating characteristic curve (AUROC) of 0.90 [95% confidence intervals (CI) 0.80-1.00] during internal validation. In the external cohort, the AUROC was 0.79 (95% CI 0.75-0.84). CONCLUSIONS: ML models combining ECG time-series features and clinical variables were able to predict non-arrhythmic mortality within three years after device implantation in a primary prevention population, with robust performance in an independent cohort.


Subject(s)
Defibrillators, Implantable , Humans , Female , Male , Patient Selection , Stroke Volume , Ventricular Function, Left , Machine Learning , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Primary Prevention
13.
Front Cardiovasc Med ; 10: 1211322, 2023.
Article in English | MEDLINE | ID: mdl-37547247

ABSTRACT

Background: The European Society of Cardiology 2019 Guidelines on chronic coronary syndrome (CCS) recommend echocardiographic measurement of the left ventricular function for risk stratification in all patients with CCS. Whereas CCS and valvular heart disease (VHD) share common pathophysiological pathways and risk factors, data on the impact of VHD in CCS patients are scarce. Methods: Clinical data including treatment and mortality of patients diagnosed with CCS who underwent comprehensive transthoracic echocardiography (TTE) in two tertiary centers were collected. The outcome was all-cause mortality. Data were analyzed with Kaplan-Meier curves and Cox proportional hazard analysis adjusting for significant covariables and time-dependent treatment. Results: Between 2014 and 2021 a total of 1,984 patients with CCS (59% men) with a median age of 65 years (interquartile range [IQR] 57-73) underwent comprehensive TTE. Severe VHD was present in 44 patients and moderate VHD in 325 patients. A total of 654 patients (33%) were treated with revascularization, 39 patients (2%) received valve repair or replacement and 299 patients (15%) died during the median follow-up time of 3.5 years (IQR 1.7-5.6). Moderate or severe VHD (hazard ratio = 1.33; 95% CI 1.02-1.72) was significantly associated with mortality risk, independent of LV function and other covariables, as compared to no/mild VHD. Conclusions: VHD has a significant impact on mortality in patients with CCS additional to LV dysfunction, which emphasizes the need for a comprehensive echocardiographic assessment in these patients.

14.
Comput Biol Med ; 164: 107266, 2023 09.
Article in English | MEDLINE | ID: mdl-37494823

ABSTRACT

Since the onset of computer-aided diagnosis in medical imaging, voxel-based segmentation has emerged as the primary methodology for automatic analysis of left ventricle (LV) function and morphology in cardiac magnetic resonance images (CMRI). In standard clinical practice, simultaneous multi-slice 2D cine short-axis MR imaging is performed under multiple breath-holds resulting in highly anisotropic 3D images. Furthermore, sparse-view CMRI often lacks whole heart coverage caused by large slice thickness and often suffers from inter-slice misalignment induced by respiratory motion. Therefore, these volumes only provide limited information about the true 3D cardiac anatomy which may hamper highly accurate assessment of functional and anatomical abnormalities. To address this, we propose a method that learns a continuous implicit function representing 3D LV shapes by training an auto-decoder. For training, high-resolution segmentations from cardiac CT angiography are used. The ability of our approach to reconstruct and complete high-resolution shapes from manually or automatically obtained sparse-view cardiac shape information is evaluated by using paired high- and low-resolution CMRI LV segmentations. The results show that the reconstructed LV shapes have an unconstrained subvoxel resolution and appear smooth and plausible in through-plane direction. Furthermore, Bland-Altman analysis reveals that reconstructed high-resolution ventricle volumes are closer to the corresponding reference volumes than reference low-resolution volumes with bias of [limits of agreement] -3.51 [-18.87, 11.85] mL, and 12.96 [-10.01, 35.92] mL respectively. Finally, the results demonstrate that the proposed approach allows recovering missing shape information and can indirectly correct for limited motion-induced artifacts.


Subject(s)
Heart , Magnetic Resonance Imaging, Cine , Magnetic Resonance Imaging, Cine/methods , Heart/diagnostic imaging , Magnetic Resonance Imaging , Heart Ventricles , Ventricular Function, Left
15.
Nat Rev Cardiol ; 20(10): 696-714, 2023 10.
Article in English | MEDLINE | ID: mdl-37277608

ABSTRACT

The detection and characterization of coronary artery stenosis and atherosclerosis using imaging tools are key for clinical decision-making in patients with known or suspected coronary artery disease. In this regard, imaging-based quantification can be improved by choosing the most appropriate imaging modality for diagnosis, treatment and procedural planning. In this Consensus Statement, we provide clinical consensus recommendations on the optimal use of different imaging techniques in various patient populations and describe the advances in imaging technology. Clinical consensus recommendations on the appropriateness of each imaging technique for direct coronary artery visualization were derived through a three-step, real-time Delphi process that took place before, during and after the Second International Quantitative Cardiovascular Imaging Meeting in September 2022. According to the Delphi survey answers, CT is the method of choice to rule out obstructive stenosis in patients with an intermediate pre-test probability of coronary artery disease and enables quantitative assessment of coronary plaque with respect to dimensions, composition, location and related risk of future cardiovascular events, whereas MRI facilitates the visualization of coronary plaque and can be used in experienced centres as a radiation-free, second-line option for non-invasive coronary angiography. PET has the greatest potential for quantifying inflammation in coronary plaque but SPECT currently has a limited role in clinical coronary artery stenosis and atherosclerosis imaging. Invasive coronary angiography is the reference standard for stenosis assessment but cannot characterize coronary plaques. Finally, intravascular ultrasonography and optical coherence tomography are the most important invasive imaging modalities for the identification of plaques at high risk of rupture. The recommendations made in this Consensus Statement will help clinicians to choose the most appropriate imaging modality on the basis of the specific clinical scenario, individual patient characteristics and the availability of each imaging modality.


Subject(s)
Atherosclerosis , Coronary Artery Disease , Coronary Stenosis , Plaque, Atherosclerotic , Humans , Coronary Artery Disease/diagnostic imaging , Constriction, Pathologic , Coronary Stenosis/diagnostic imaging , Coronary Angiography/methods , Plaque, Atherosclerotic/diagnostic imaging
16.
Neuroimage Clin ; 38: 103411, 2023.
Article in English | MEDLINE | ID: mdl-37163913

ABSTRACT

The olfactory bulbs (OBs) play a key role in olfactory processing; their volume is important for diagnosis, prognosis and treatment of patients with olfactory loss. Until now, measurements of OB volumes have been limited to quantification of manually segmented OBs, which is a cumbersome task and makes evaluation of OB volumes in large scale clinical studies infeasible. Hence, the aim of this study was to evaluate the potential of our previously developed automatic OB segmentation method for application in clinical practice and to relate the results to clinical outcome measures. To evaluate utilization potential of the automatic segmentation method, three data sets containing MR scans of patients with olfactory loss were included. Dataset 1 (N = 66) and 3 (N = 181) were collected at the Smell and Taste Center in Ede (NL) on a 3 T scanner; dataset 2 (N = 42) was collected at the Smell and Taste Clinic in Dresden (DE) on a 1.5 T scanner. To define the reference standard, manual annotation of the OBs was performed in Dataset 1 and 2. OBs were segmented with a method that employs two consecutive convolutional neural networks (CNNs) that the first localize the OBs in an MRI scan and subsequently segment them. In Dataset 1 and 2, the method accurately segmented the OBs, resulting in a Dice coefficient above 0.7 and average symmetrical surface distance below 0.3 mm. Volumes determined from manual and automatic segmentations showed a strong correlation (Dataset 1: r = 0.79, p < 0.001; Dataset 2: r = 0.72, p = 0.004). In addition, the method was able to recognize the absence of an OB. In Dataset 3, OB volumes computed from automatic segmentations obtained with our method were related to clinical outcome measures, i.e. duration and etiology of olfactory loss, and olfactory ability. We found that OB volume was significantly related to age of the patient, duration and etiology of olfactory loss, and olfactory ability (F(5, 172) = 11.348, p < 0.001, R2 = 0.248). In conclusion, the results demonstrate that automatic segmentation of the OBs and subsequent computation of their volumes in MRI scans can be performed accurately and can be applied in clinical and research population studies. Automatic evaluation may lead to more insight in the role of OB volume in diagnosis, prognosis and treatment of olfactory loss.


Subject(s)
Neural Networks, Computer , Olfactory Bulb , Humans , Olfactory Bulb/diagnostic imaging , Smell , Magnetic Resonance Imaging/methods
17.
Neuroimage Clin ; 38: 103381, 2023.
Article in English | MEDLINE | ID: mdl-36965456

ABSTRACT

BACKGROUND: Perinatal arterial ischemic stroke (PAIS) is associated with adverse neurological outcomes. Quantification of ischemic lesions and consequent brain development in newborn infants relies on labor-intensive manual assessment of brain tissues and ischemic lesions. Hence, we propose an automatic method utilizing convolutional neural networks (CNNs) to segment brain tissues and ischemic lesions in MRI scans of infants suffering from PAIS. MATERIALS AND METHODS: This single-center retrospective study included 115 patients with PAIS that underwent MRI after the stroke onset (baseline) and after three months (follow-up). Nine baseline and 12 follow-up MRI scans were manually annotated to provide reference segmentations (white matter, gray matter, basal ganglia and thalami, brainstem, ventricles, extra-ventricular cerebrospinal fluid, and cerebellum, and additionally on the baseline scans the ischemic lesions). Two CNNs were trained to perform automatic segmentation on the baseline and follow-up MRIs, respectively. Automatic segmentations were quantitatively evaluated using the Dice coefficient (DC) and the mean surface distance (MSD). Volumetric agreement between segmentations that were manually and automatically obtained was computed. Moreover, the scan quality and automatic segmentations were qualitatively evaluated in a larger set of MRIs without manual annotation by two experts. In addition, the scan quality was qualitatively evaluated in these scans to establish its impact on the automatic segmentation performance. RESULTS: Automatic brain tissue segmentation led to a DC and MSD between 0.78-0.92 and 0.18-1.08 mm for baseline, and between 0.88-0.95 and 0.10-0.58 mm for follow-up scans, respectively. For the ischemic lesions at baseline the DC and MSD were between 0.72-0.86 and 1.23-2.18 mm, respectively. Volumetric measurements indicated limited oversegmentation of the extra-ventricular cerebrospinal fluid in both the follow-up and baseline scans, oversegmentation of the ischemic lesions in the left hemisphere, and undersegmentation of the ischemic lesions in the right hemisphere. In scans without imaging artifacts, brain tissue segmentation was graded as excellent in more than 85% and 91% of cases, respectively for the baseline and follow-up scans. For the ischemic lesions at baseline, this was in 61% of cases. CONCLUSIONS: Automatic segmentation of brain tissue and ischemic lesions in MRI scans of patients with PAIS is feasible. The method may allow evaluation of the brain development and efficacy of treatment in large datasets.


Subject(s)
Infant, Newborn, Diseases , Ischemic Stroke , Infant, Newborn , Pregnancy , Female , Humans , Retrospective Studies , Image Processing, Computer-Assisted/methods , Brain/diagnostic imaging , Magnetic Resonance Imaging/methods
18.
Eur J Cancer ; 185: 167-177, 2023 05.
Article in English | MEDLINE | ID: mdl-36996627

ABSTRACT

INTRODUCTION: Predicting checkpoint inhibitors treatment outcomes in melanoma is a relevant task, due to the unpredictable and potentially fatal toxicity and high costs for society. However, accurate biomarkers for treatment outcomes are lacking. Radiomics are a technique to quantitatively capture tumour characteristics on readily available computed tomography (CT) imaging. The purpose of this study was to investigate the added value of radiomics for predicting clinical benefit from checkpoint inhibitors in melanoma in a large, multicenter cohort. METHODS: Patients who received first-line anti-PD1±anti-CTLA4 treatment for advanced cutaneous melanoma were retrospectively identified from nine participating hospitals. For every patient, up to five representative lesions were segmented on baseline CT, and radiomics features were extracted. A machine learning pipeline was trained on the radiomics features to predict clinical benefit, defined as stable disease for more than 6 months or response per RECIST 1.1 criteria. This approach was evaluated using a leave-one-centre-out cross validation and compared to a model based on previously discovered clinical predictors. Lastly, a combination model was built on the radiomics and clinical model. RESULTS: A total of 620 patients were included, of which 59.2% experienced clinical benefit. The radiomics model achieved an area under the receiver operator characteristic curve (AUROC) of 0.607 [95% CI, 0.562-0.652], lower than that of the clinical model (AUROC=0.646 [95% CI, 0.600-0.692]). The combination model yielded no improvement over the clinical model in terms of discrimination (AUROC=0.636 [95% CI, 0.592-0.680]) or calibration. The output of the radiomics model was significantly correlated with three out of five input variables of the clinical model (p < 0.001). DISCUSSION: The radiomics model achieved a moderate predictive value of clinical benefit, which was statistically significant. However, a radiomics approach was unable to add value to a simpler clinical model, most likely due to the overlap in predictive information learned by both models. Future research should focus on the application of deep learning, spectral CT-derived radiomics, and a multimodal approach for accurately predicting benefit to checkpoint inhibitor treatment in advanced melanoma.


Subject(s)
Melanoma , Skin Neoplasms , Humans , Melanoma/diagnostic imaging , Melanoma/drug therapy , Skin Neoplasms/diagnostic imaging , Skin Neoplasms/drug therapy , Retrospective Studies , Treatment Outcome , Tomography, X-Ray Computed
19.
Eur J Radiol ; 159: 110687, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36610325

ABSTRACT

BACKGROUND: Computed tomography (CT)-detected aortic calcification is strongly associated with aortic stiffness and is an accurate predictor of cardiovascular and all-cause mortality and cognitive decline. Some previous pathologic studies have shown calcium accumulation in the medial layer of the vessel wall, while others have suggested localisation in the atherosclerotic intimal layer. OBJECTIVES: The aim of this study was to histologically validate CT findings of aortic calcification for detectability and location in the aortic wall. METHODS: We acquired postmortem CT images and collected 170 aortic tissue samples from five different locations in the thoracic and abdominal aorta of 40 individuals who underwent autopsy. Microscopic slides were stained with haematoxylin and eosin and elastic van Gieson stain. Calcified lesions were characterised and calcifications were manually annotated in the intima and media. The presence and morphology of calcifications were scored on CT images. RESULTS: The mean age of the autopsied individuals was 63 years, and 28 % died of cardiovascular disease. Calcifications were present in 74/170 (44 %) samples. Calcification was more common in the abdominal aorta than in the thoracic aorta. In all samples with calcifications, 99 % were located in the intimal layer. Only 16/170 samples had a small amount of medial arterial calcification. The histological results showed an 85 % concordance for the presence or absence of CT calcifications. There was complete inter-method agreement for annularity of calcifications in 68 % of the samples (linear weighted kappa 0.68 (95 %CI 0.60-0.77). CONCLUSIONS: Aortic calcifications visible on CT are located in the intimal layer of the abdominal aorta wall, at least in aortas that are not aneurysmatic or dissected. The presence and annularity of these calcifications can be reliably determined by CT.


Subject(s)
Aortic Diseases , Calcinosis , Vascular Calcification , Middle Aged , Humans , Calcinosis/pathology , Tomography, X-Ray Computed/adverse effects , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/pathology , Aorta, Abdominal/diagnostic imaging , Carotid Intima-Media Thickness , Aortic Diseases/diagnostic imaging , Vascular Calcification/diagnostic imaging , Vascular Calcification/pathology
20.
Clin Res Cardiol ; 112(3): 363-378, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36066609

ABSTRACT

BACKGROUND: Arrhythmogenic right ventricular cardiomyopathy (ARVC) is diagnosed according to the Task Force Criteria (TFC) in which cardiovascular magnetic resonance (CMR) imaging plays an important role. Our study aims to apply an automatic deep learning-based segmentation for right and left ventricular CMR assessment and evaluate this approach for classification of the CMR TFC. METHODS: We included 227 subjects suspected of ARVC who underwent CMR. Subjects were classified into (1) ARVC patients fulfilling TFC; (2) at-risk family members; and (3) controls. To perform automatic segmentation, a Bayesian Dilated Residual Neural Network was trained and tested. Performance of automatic versus manual segmentation was assessed using Dice-coefficient and Hausdorff distance. Since automatic segmentation is most challenging in basal slices, manual correction of the automatic segmentation in the most basal slice was simulated (automatic-basal). CMR TFC calculated using manual and automatic-basal segmentation were compared using Cohen's Kappa (κ). RESULTS: Automatic segmentation was trained on CMRs of 70 subjects (39.6 ± 18.1 years, 47% female) and tested on 157 subjects (36.9 ± 17.6 years, 59% female). Dice-coefficient and Hausdorff distance showed good agreement between manual and automatic segmentations (≥ 0.89 and ≤ 10.6 mm, respectively) which further improved after simulated correction of the most basal slice (≥ 0.92 and ≤ 9.2 mm, p < 0.001). Pearson correlation of volumetric and functional CMR measurements was good to excellent (automatic (r = 0.78-0.99, p < 0.001) and automatic-basal (r = 0.88-0.99, p < 0.001) measurements). CMR TFC classification using automatic-basal segmentations was comparable to manual segmentations (κ 0.98 ± 0.02) with comparable diagnostic performance. CONCLUSIONS: Combining automatic segmentation of CMRs with correction of the most basal slice results in accurate CMR TFC classification of subjects suspected of ARVC.


Subject(s)
Arrhythmogenic Right Ventricular Dysplasia , Humans , Female , Male , Arrhythmogenic Right Ventricular Dysplasia/diagnostic imaging , Bayes Theorem , Magnetic Resonance Imaging, Cine/methods , Magnetic Resonance Imaging , Heart Ventricles , Magnetic Resonance Spectroscopy
SELECTION OF CITATIONS
SEARCH DETAIL
...